************************ 07/13/2007 16:56:48 MERIT Configuration Data Test Description: Remote control from ORNL. Initial testing with optics. Mode = Manual LogFile = C:\MERIT Data\070713 logfile.txt Trigger-Pulse Delay (s) = 16.500000 FlatTop Pct = 0.800000 Jet Accel Time (s) = 6.000000 Jet Steady State Time (s) = 2.000000 Jet Decel Time (s) = 2.000000 Jet SS Velocity (cm/s) = 500.000000 Hg Prefill Vol (liter) = 1.000000 Cylinder Retract Speed (cm/s) = 0.500000 Nozzle Dia (cm) = 1.020000 Hg Volume (liter) = 13.700000 Hg Pressure Alarm (bar) = 80.000000 Hg Temperature Alarm (C) = 30.000000 Hyd Fluid Temp Alarm Level (C) = 55.000000 Hg Cyl Inlet Temp Alarm (C) = 30.000000 Sec Air Temp Alarm (C) = 30.000000 Down Pri Win Temp Alarm (C) = 40.000000 Down Bore Air Temp Alarm (min) (C) = 15.000000 Up Bore Air Temp Alarm (min) (C) = 15.000000 Flange Temp Alarm (C) = 30.000000 Upstream Window Alarm (mbar) = 200.000000 Downstream Window Alarm (mbar) = 200.000000 Hg VaporMonitor 1 Alarm (mg/m^3) = 0.100000 Hg VaporMonitor 2 Alarm (mg/m^3) = 0.100000 ************************ 07/13/2007 16:56:48 Log File Opened. Sensor data below. Data is tab-delimited: copy-paste into spreadsheet for proper formatting. Timestamp Hg Sump Level (cm) Hg Temp (C) HydFluid Temp (C) HgCylInlet Temp (C) Sec Air Temp (C) Dn Pri Win Temp (C) Dn Bore Temp (C) Up Bore Temp (C) Flange Temp (C) Jerome Hg Vapor (mg/m^3) VM3000 Hg Vapor (mg/m^3) Port A Pressure (bar) Port B Pressure (bar) 07/13/2007 16:57:32 5.5 19.8 22.8 21.5 21.8 21.4 21.4 21.4 21.5 0.001 0.021 -0.3 -1.0 07/13/2007 16:58:33 5.5 19.8 22.8 21.4 21.8 21.4 21.4 21.4 21.5 0.000 0.022 -0.4 -1.0 07/13/2007 16:59:33 5.5 19.7 22.8 21.5 21.8 21.4 21.4 21.4 21.5 0.000 0.022 -0.2 -1.1 07/13/2007 17:00:08 Hydraulic system powered on. ************************ 07/27/2007 10:47:42 MERIT Configuration Data Test Description: Remote control from ORNL. Initial testing with optics. Mode = Manual LogFile = C:\MERIT Data\070713 logfile.txt Trigger-Pulse Delay (s) = 16.500000 FlatTop Pct = 0.800000 Jet Accel Time (s) = 6.000000 Jet Steady State Time (s) = 2.000000 Jet Decel Time (s) = 2.000000 Jet SS Velocity (cm/s) = 500.000000 Hg Prefill Vol (liter) = 1.000000 Cylinder Retract Speed (cm/s) = 0.500000 Nozzle Dia (cm) = 1.020000 Hg Volume (liter) = 13.700000 Hg Pressure Alarm (bar) = 80.000000 Hg Temperature Alarm (C) = 30.000000 Hyd Fluid Temp Alarm Level (C) = 55.000000 Hg Cyl Inlet Temp Alarm (C) = 30.000000 Sec Air Temp Alarm (C) = 30.000000 Down Pri Win Temp Alarm (C) = 40.000000 Down Bore Air Temp Alarm (min) (C) = 15.000000 Up Bore Air Temp Alarm (min) (C) = 15.000000 Flange Temp Alarm (C) = 30.000000 Upstream Window Alarm (mbar) = 200.000000 Downstream Window Alarm (mbar) = 200.000000 Hg VaporMonitor 1 Alarm (mg/m^3) = 0.100000 Hg VaporMonitor 2 Alarm (mg/m^3) = 0.100000 ************************ 07/27/2007 10:47:42 Log File Opened. 07/27/2007 10:47:48 Hydraulic system powered on. 07/27/2007 10:47:53 Syringe extension started. Syringe current position = -1.81 Syringe extended position = -6.81 Syringe ready position = -4.84 07/27/2007 10:48:37 User aborted retract operation. ************************ 07/27/2007 11:05:06 MERIT Configuration Data Test Description: Remote control from ORNL. Initial testing with optics. Mode = Manual LogFile = C:\MERIT Data\070713 logfile.txt Trigger-Pulse Delay (s) = 16.500000 FlatTop Pct = 0.800000 Jet Accel Time (s) = 6.000000 Jet Steady State Time (s) = 2.000000 Jet Decel Time (s) = 2.000000 Jet SS Velocity (cm/s) = 500.000000 Hg Prefill Vol (liter) = 1.000000 Cylinder Retract Speed (cm/s) = 0.500000 Nozzle Dia (cm) = 1.020000 Hg Volume (liter) = 13.700000 Hg Pressure Alarm (bar) = 80.000000 Hg Temperature Alarm (C) = 30.000000 Hyd Fluid Temp Alarm Level (C) = 55.000000 Hg Cyl Inlet Temp Alarm (C) = 30.000000 Sec Air Temp Alarm (C) = 30.000000 Down Pri Win Temp Alarm (C) = 40.000000 Down Bore Air Temp Alarm (min) (C) = 15.000000 Up Bore Air Temp Alarm (min) (C) = 15.000000 Flange Temp Alarm (C) = 30.000000 Upstream Window Alarm (mbar) = 200.000000 Downstream Window Alarm (mbar) = 200.000000 Hg VaporMonitor 1 Alarm (mg/m^3) = 0.100000 Hg VaporMonitor 2 Alarm (mg/m^3) = 0.100000 ************************ 07/27/2007 11:05:06 Log File Opened. 07/27/2007 11:05:22 Syringe extension started. Syringe current position = -1.81 Syringe extended position = -6.81 Syringe ready position = -4.84 07/27/2007 11:06:17 User aborted retract operation. Sensor data below. Data is tab-delimited: copy-paste into spreadsheet for proper formatting. Timestamp Hg Sump Level (cm) Hg Temp (C) HydFluid Temp (C) HgCylInlet Temp (C) Sec Air Temp (C) Dn Pri Win Temp (C) Dn Bore Temp (C) Up Bore Temp (C) Flange Temp (C) Jerome Hg Vapor (mg/m^3) VM3000 Hg Vapor (mg/m^3) Port A Pressure (bar) Port B Pressure (bar) 07/27/2007 11:06:18 5.5 20.0 23.4 21.7 22.1 21.8 21.7 21.7 21.9 0.001 0.020 -0.3 -0.8 07/27/2007 11:06:22 Homing cylinder. Cylinder current position = -1.81 ************************ 07/27/2007 11:08:30 MERIT Configuration Data Test Description: Remote control from ORNL. Initial testing with optics. Mode = Manual LogFile = C:\MERIT Data\070713 logfile.txt Trigger-Pulse Delay (s) = 16.500000 FlatTop Pct = 0.800000 Jet Accel Time (s) = 6.000000 Jet Steady State Time (s) = 2.000000 Jet Decel Time (s) = 2.000000 Jet SS Velocity (cm/s) = 500.000000 Hg Prefill Vol (liter) = 1.000000 Cylinder Retract Speed (cm/s) = 0.500000 Nozzle Dia (cm) = 1.020000 Hg Volume (liter) = 13.700000 Hg Pressure Alarm (bar) = 80.000000 Hg Temperature Alarm (C) = 30.000000 Hyd Fluid Temp Alarm Level (C) = 55.000000 Hg Cyl Inlet Temp Alarm (C) = 30.000000 Sec Air Temp Alarm (C) = 30.000000 Down Pri Win Temp Alarm (C) = 40.000000 Down Bore Air Temp Alarm (min) (C) = 15.000000 Up Bore Air Temp Alarm (min) (C) = 15.000000 Flange Temp Alarm (C) = 30.000000 Upstream Window Alarm (mbar) = 200.000000 Downstream Window Alarm (mbar) = 200.000000 Hg VaporMonitor 1 Alarm (mg/m^3) = 0.100000 Hg VaporMonitor 2 Alarm (mg/m^3) = 0.100000 ************************ 07/27/2007 11:08:31 Log File Opened. 07/27/2007 11:08:34 Syringe extension started. Syringe current position = -1.81 Syringe extended position = -6.81 Syringe ready position = -4.84 07/27/2007 11:08:57 User aborted retract operation. 07/27/2007 11:08:59 Homing cylinder. Cylinder current position = -1.83 07/27/2007 11:09:14 User aborted Home operation. Sensor data below. Data is tab-delimited: copy-paste into spreadsheet for proper formatting. Timestamp Hg Sump Level (cm) Hg Temp (C) HydFluid Temp (C) HgCylInlet Temp (C) Sec Air Temp (C) Dn Pri Win Temp (C) Dn Bore Temp (C) Up Bore Temp (C) Flange Temp (C) Jerome Hg Vapor (mg/m^3) VM3000 Hg Vapor (mg/m^3) Port A Pressure (bar) Port B Pressure (bar) 07/27/2007 11:09:15 5.4 20.0 23.4 21.7 22.1 21.8 21.7 21.7 21.9 0.000 0.020 -0.3 -0.8 07/27/2007 11:09:17 Syringe extension started. Syringe current position = -1.81 Syringe extended position = -6.81 Syringe ready position = -4.84 07/27/2007 11:09:25 User aborted retract operation. 07/27/2007 11:09:28 Homing cylinder. Cylinder current position = -1.81 07/27/2007 11:11:03 User aborted Home operation. 07/27/2007 11:11:03 Syringe extension started. Syringe current position = -1.81 Syringe extended position = -6.81 Syringe ready position = -4.84 07/27/2007 11:11:32 User aborted retract operation. 07/27/2007 11:11:32 Syringe extension started. Syringe current position = -1.81 Syringe extended position = -6.81 Syringe ready position = -4.84 07/27/2007 11:11:34 User aborted retract operation. Sensor data below. Data is tab-delimited: copy-paste into spreadsheet for proper formatting. Timestamp Hg Sump Level (cm) Hg Temp (C) HydFluid Temp (C) HgCylInlet Temp (C) Sec Air Temp (C) Dn Pri Win Temp (C) Dn Bore Temp (C) Up Bore Temp (C) Flange Temp (C) Jerome Hg Vapor (mg/m^3) VM3000 Hg Vapor (mg/m^3) Port A Pressure (bar) Port B Pressure (bar) 07/27/2007 11:11:35 5.4 20.0 23.4 21.8 22.1 21.8 21.7 21.8 21.9 0.000 0.020 -0.3 -0.8 07/27/2007 11:11:38 Homing cylinder. Cylinder current position = -1.81 07/27/2007 11:11:47 User aborted Home operation. 07/27/2007 11:11:50 Hydraulic system powered off.